Server Name
|
Server Model
|
CPU
|
RAID
|
Disk
|
NIC
|
Others
|
|
TaiShan 200
|
2280E edge model
|
Kunpeng 920
|
LSI SAS3008
|
NVME SSD, SAS, SATA
|
Onboard HNS3 NIC, Hi1822, Intel_82599, Intel_X710, and DPU_SP923D (only 2280 balanced model)
|
-
|
|
1280 high-density
|
LSI SAS3408
|
-
|
||||
|
2280 balanced model
|
LSI SAS3508
|
SDI 2.0 accelerator card: IT21SHSB
|
||||
|
|
SDI 3.0 accelerator card: IT21SHSC
|
|||||
|
2480 high-performance
|
|
-
|
||||
|
5280 storage model
|
|
-
|
||||
|
X6000 high-density model
|
|
-
|
||||
|
XA320 high-density model
|
|
-
|
||||
|
2180 balanced model
|
|
-
|
||||
|
TaiShan 100
|
2280 balanced model
|
Huawei Kunpeng 916
|
LSI SAS3008
|
NVME SSD, SAS, SATA
|
Onboard HNS3 NIC, Hi1822
|
-
|
|
5280 storage model
|
-
|
|||||
|
Atlas 500 Pro
|
Model 3000 (Ascend)
|
Kunpeng 920 3210
|
N/A
|
SATA, SAS
|
Onboard HNS NIC
|
-
|
|
OceanStor Dorado 6000
|
V6 (SAS)
|
Kunpeng 920
|
N/A
|
SAS, SSD, and SATA
|
Hi1822
|
-
|
|
V6 (smart SAS)
|
-
|
|||||
|
V6 (NVMe)
|
PALM NVMe, NVMe SSD, SATA
|
-
|
||||
|
OceanStor Dorado 5000
|
V6 (SAS)
|
Kunpeng 920
|
N/A
|
SAS, SSD, and SATA
|
Hi1822
|
-
|
|
V6 (smart SAS)
|
-
|
|||||
|
V6 (NVMe)
|
PALM NVMe, NVMe SSD, SATA
|
-
|
||||
|
OceanStor Pacific 9520
|
VE
|
Kunpeng 920 5220 processor
|
N/A
|
SATA, SAS
|
Onboard NIC
|
-
|
|
China Electronics Cyberspace Great Wall
|
QingTian DF729
|
FT2000+/2.2 GHz/1 x 64-core
|
LSI 3108
|
SSD, SAS, SATA
|
Intel_82599ES
|
Due to hardware design reasons, the CPU of China Electronics Cyberspace Great Wall does not support the following features:
|
|
RAS
|
||||||
|
Bringing CPU online or offline
|
||||||
|
The dmidecode command cannot be used to obtain hardware information due to the incorrect BIOS version of the server.
|
||||||
|
The TPM security chip is not installed. Trusted boot is not supported.
|
||||||
|
The Huawei Cloud public key certificate fails to be imported to the BIOS. Huawei Cloud secure boot is not supported.
|
||||||
|
Due to the hardware features of Phytium S2500, you need to change the value of KDUMP_COMMANDLINE_APPEND from "nr_cpus=1" to "nr_cpus=2" in the /etc/sysconfig/kdump file. After the modification, run the聽systemctl restart kdump聽command to restart the kdump service.
|
||||||
|
QingTian EF860
|
S2500+/2.1 GHz/2 x 64-core
|
LSI 3108
|
SSD, SAS, SATA, NVME
|
Mellanox CX5
|
Performance-related metrics are not guaranteed.
|
|
|
Atlas 800
|
9000
|
Kunpeng 920
|
LSI SAS3508
|
SAS
|
Onboard NIC, Hi1822
|
The SDI 3.0 accelerator card is supported.
|
|
Bringing CPU0 online or offline is not supported.
|
||||||
|
Atlas 800D
|
G1
|
Hi1951AG
|
N/A
|
EMMC
|
Hi1822
|
Bringing CPU online or offline is not supported.
|
|
Hi1951PG*2
|
Memory hot swap is not supported.
|
|||||
|
|
The聽gdb print聽command cannot be used to invoke functions.
|
|||||
|
|
Performance-related metrics are not guaranteed.
|
|||||
|
PoweLeader
|
BD-21083F3
|
Phytium S2500 * 2
|
AVAGO MegaRAID SAS 9460-8i
|
SAS
|
Huawei SP333
|
Performance-related metrics are not guaranteed.
|
|
Table A-3聽Supported hardware servers (x86)
|
|
|
|
|
|
|
|
General-purpose x86 servers
|
CPU
|
RAID
|
Disk
|
NIC
|
Others
|
|
|
Huawei 2288/2288H/2288X/2285 V3/V4/V5
|
Ivy Bridge, Broadwell, and Purley architectures. For example:
|
LSI SAS3008, LSI SAS3108, LSI SAS3408, LSI SAS3508, LSI SAS3516
|
NVME SSD, SAS, SATA, SMR
|
Intel_X722, Intel_82599, Intel_I350, Intel_X710, Intel_82576, Hi1822, Broadcom BCM5709, Broadcom BCM5719
|
TPM 2.0.
|
|
|
Huawei 5288/5885 V3/V4/V5
|
E7-8890, E5-2407, E5-2603, E5-2620, E5-2650, E5-2658, E5-2699, E5-2680, E5-2683, E5620, Silver_3104, Silver_4109, Silver_4114, Gold_5118, Gold_5120, Gold 5220R, Gold 6138, Gold 6154, Gold 6161
|
SDI 3.5 accelerator card: IT21SHSE. Bringing CPU online or offline is not supported.
|
|
|||
|
Huawei 1288 V3/V4/V5
|
|
|
|
|||
|
Huawei E9000 V3/V4/V5
|
|
|
|
|||
|
Huawei E9000H
|
Icelake 6338N
|
-
|
SSD
|
Intel XXV710
|
The TPM security chip is not installed. Trusted boot is not supported.
|
|
|
The BIOS does not support secure boot.
|
|
|||||
|
Huawei 2288H V6
|
Ice lake-SP Xeon Platinum 8378A (customized for the public cloud and not for other product lines)
|
-
|
-
|
-
|
-
|
|
|
Gold 6330
|
-
|
SAS, SATA
|
Intel l350
|
-
|
|
|
|
MiTAC NV680/681
|
AMD EPYC 7742
|
-
|
SAS, SATA
|
Mellanox CX5
|
Performance-related metrics are not guaranteed.
|
|
|
MiTAC TYAN
|
AMD EPYC 7713 64-Core Processor
|
-
|
SAS, SATA
|
BCM5720
|
Performance-related metrics are not guaranteed.
|
|
|
Lenovo SR658H
|
Hygon7165/7151(AMD)
|
-
|
SAS, SATA
|
-
|
Performance-related metrics are not guaranteed.
|
|
|
Inspur NF5280M4
|
E5-2640
|
-
|
SAS, SATA
|
Onboard NIC
|
Performance-related metrics are not guaranteed.
|
|
|
Inspur NF5280M5
|
Gold 5118
|
-
|
SAS, SATA
|
Intel_X710
|
Performance-related metrics are not guaranteed.
|
|
|
FusionCube500
|
Gold 6330, Silver 4316, Silver 4314
|
-
|
-
|
Intel_I210
|
-
|
|
|
FusionPoD liquid-cooled DH120C V6
|
Intel(R) Xeon(R) Platinum 8378A
|
LSI SAS3508
|
-
|
Mellanox CX5
|
-
|
|
|
Luxshare-ICT Luxshare ABS
|
AMD EPYC 7713 64-Core Processor
|
-
|
SATA
|
mlx CX-5
|
Performance-related metrics are not guaranteed.
|
|
|
SuperCloud R3216 (Hygon)
|
Hygon C86 7255 16-core Processor
|
LSI SAS 3108
|
SATA
|
Intel I350
|
Performance-related metrics are not guaranteed.
|
|
|
Mellanox CX4
|
|
|||||
|
xFusion 2288H V6
|
Intel(R) Xeon(R) Gold 6348 CPU
|
-
|
SATA
|
mlx CX-5
|
Performance-related metrics are not guaranteed.
|
|
|
mlx CX-6
|
|
|||||
|
Table A-4聽Minimum hardware specifications supported
|
|
|
|
|
|
|
|
Component Name
|
Minimal Hardware Specifications
|
Description
|
|
|
|
|
|
Architecture
|
Aarch64/x86_64
|
Only the HiSilicon Hi1616 and Hi1620 are supported for the AArch64 architecture.
|
|
|
|
|
|
Intel/AMD x86-64 CPUs are supported for In the x86 architecture.
|
|
|
|
|
||
|
CPU
|
General scenarios
|
It is highly recommended that the CPUs of physical servers used as computing nodes in one cluster be the same type.
|
|
|
|
|
|
PM:
|
|
|
|
|
||
|
Aarch64: Kunpeng 916/920
|
|
|
|
|
||
|
x86-64: Intel/AMD x86-64
|
|
|
|
|
||
|
VM: The number of CPU cores is greater than or equal to 1.
|
|
|
|
|
||
|
Tailored products
|
|
|
|
|
||
|
Aarch64: Kunpeng 916/920
|
|
|
|
|
||
|
x86-64: Intel/AMD x86-64
|
|
|
|
|
||
|
Memory
|
General scenarios
|
-
|
|
|
|
|
|
PM: at least 8 GB
|
|
|
|
|
||
|
VM: at least 1 GB for CD-ROM mounting and at least 2 GB for PXE installation
|
|
|
|
|
||
|
Tailored product: no less than 4 GB
|
-
|
|
|
|
|
|
|
Disk
|
At least one hard disk with the space larger than 120 GB is required.
|
The hard disk supports IDE, SATA, SAS interfaces.
|
|
|
|
|
|
The SD card larger than 32 GB cannot be partitioned, for example, the SDHC and SDXC cards.
|
|
|
|
|
||
|
Network Port
|
>= 1. Six NICs are recommended to ensure services and network reliability.
|
At least one NIC supports PXE. If no NIC supports PXE, automatic deployment is not supported. All NIC rates must be greater than 1,000 Mbit/s.
|
|
|
|
|
|
(Optional) RAID controller card
|
One RAID disk group maps one logical disk.
|
Because RAID improves disk reliability, disks must be used in RAID disk group, not as individual disks.
|
|
|
|
|
|
The LSI3008 or LSI3108 RAID controller card is supported.
|
|
|
|
|
||
|
(Optional) HBA
|
No special requirements
|
If FC SAN storage devices are used, HBAs are a must.
|
|
|
|
|
|
(Optional) BMC/IPMI
|
Compliant with IPMI specifications
|
It is recommended that the component be offered.
|
|
|
|
|
|
(Optional) USB interface
|
USB 2.0 or later standard interface
|
USB ports can be used to boot the OS from the USB or USB drive.
|
|
|
|
|
|
(Optional) CD-ROM
|
Standard CD-ROM/DVD-ROM drive
|
You can use the CD-ROM for installation.
|
|
|
|
|
|
Others
|
Optional
|
If other hardware is required, the related drive must be available.
|
|
|
|
|
|
Table A-5聽HCC Turnkey聽extended compatibility
|
|
|
|
|
|
|
|
Hardware Type
|
Model
|
Driver
|
Architecture
|
|
|
|
|
Server
|
H3C (Hygon Gen 3)
|
N/A
|
x86
|
|
|
|
|
xFusion (Intel's fourth-generation Xeon)
|
N/A
|
x86
|
|
|
|
|
|
NIC
|
Hi1822
|
hinic
|
x86, aarch64
|
|
|
|
|
Hi1823
|
hinic3
|
aarch64
|
|
|
|
|
|
Web communications
|
Off-site drive installation
|
x86
|
|
|
|
|
|
Raid
|
SAS3908(9560)
|
megaraid_sas
|
x86, aarch64
|
|
|
|
|
SAS3508(9560)
|
megaraid_sas
|
x86, aarch64
|
|
|
|
|
|
Hi1880/B80121 (SP686C)
|
hiraid
|
|
|
|
|
|